FaultPoint™ Add-in Module for PQView®

Fault analysis and location functionality in PQView is enabled via the FaultPoint™ Add-In Module. FaultPoint combines three functions: fault identification from waveform samples, estimation of impedance-to-fault from the waveforms, and display of the estimated fault location using interactive one-line diagrams and maps.

The following list is a summary of the functionality supported by FaultPoint:

  • Identifies Single-Phase Faults from Waveform Samples Recorded by Meters with the following configurations:
    • three-phase line-neutral voltage with three-phase line currents
    • three-phase line-line voltage with zero-sequence source impedance and three-phase line currents
    • three-phase line-neutral voltage with zero-sequence source impedance and no line currents
  • Identifies Multi-Phase Faults from Waveform Samples Recorded by Meters with the following configurations:
    • three-phase line-neutral voltage with three-phase line currents
    • three-phase line-line voltage and three-phase line currents
  • Identifies Start and End of Faults from Waveform Samples
  • Identifies Subcycle Faults from Waveform Samples
  • Identifies Magnetizing Transformer Inrush Current from Waveform Samples
  • Estimates Fault Location for Single-Phase Faults using One of Four Methods:
    • Reactance-to-Fault Method
    • Loop Reactance
    • Loop Impedance
    • Absolute Impedance
  • Sends E-Mail Notification for Fault Events via an SMTP Server
    • E-Mail Notification includes OSIsoft PI System event correlation if available
    • E-Mail Notification includes Digital Status Summary if Data Source is Digital Relay
  • Correlates Fault Events with SCADA Operation Events
  • Builds Fault Event Lists in PQView and WebPQView
  • Displays Estimated Fault Location on One-Line Diagram in PQView and WebPQView
  • Export of One-Line Diagram to KML Viewer such as Google Earth.
  • Creates Fault Analysis Charts and Summaries
  • Analyzes Faults using a Follow-On Fault Processing Module
  • Imports Geographic and Electrical Data for Distribution Lines from Eaton/Cooper CYMDIST Databases or Synergi Electric databases.
  • Imports and/or Derives Positive-Sequence and Zero-Sequence Impedance from CYMDIST/SynerGEE Databases
  • Converts Coordinates from Custom Projection System to Coordinates Compatible with Third-Party GIS Applications such as Google Earth.

See the chart gallery for fault analysis and fault location using FaultPoint and PQView.

 

Customer Testimonials

Paul Stergiou, Con Edison: "Recent addition of advanced fault location capability has significantly increased the value of these systems, reducing the time required to locate feeder faults at Con Edison by more than one hour."